The 4 structures are simulated with 32 ports defined on the 32 terminals
of the two meshed ground planes. The results can even be used to extract the
RLC equivalent circuit of the meshed ground. To calculate the characteristic impedance
and capacitance of the x-signal line in the structure, we need to terminate
the 32 ports of the meshed ground plane to some fixed potential. The simulation
time can be reduced significantly if we connect the meshed ground plane to fixed potential in the simulation.
The Quasi-TEM simulation results are from: A. C. Cangeliaris, M. Gribbons,and J. L. Prince, "Electrical characteristics of multichip moduleinterconnects with perforated reference planes," IEEE Trans. onComponents, Hybrids, and Manufacturing Tech., Vol. 16, No.1, pp. 113-118,Feb. 1993.
The Full-Wave (IBM) simulation results and measured results are from: B. J.Rubin, "An electromagnetic approach for modeling high performance
computer package," IBM J. Res. Develop., Vol. 34, pp. 585-600, July 1990.
Characteristic Impedance of X-Signal Line (W)